Publikationen


Suche nach „[Maschinenbau und Mechatronik]“ hat 717 Publikationen gefunden
Suchergebnis als PDF
    NachhaltigMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    Nadine Kaczmarkiewicz, Giuseppe Bonfigli, S. Leyer, T. Wagner

    Performance of the Passive Core Flooding System in the Integral Tests of the Project EASY

    49. Jahrestagung Kerntechnik / 49th Annual Meeting on Nuclear Technology (AMNT 2018), Berlin , 29. - 30. Mai 2018

    2018

    Abstract anzeigen

    Among nuclear power generation plants, light water reactors are mainly used at present, and are anticipated to be predominant in the future. To improve the light water reactors the development of the LWRs for the next generation is carried out at various organizations. For example, in the USA the Westinghouse AP-1000 is based on proven technology but with an emphasis on passive safety features. The reactor passive core cooling systems include the core makeup tanks system, passive residual heat removal heat exchanger and in-containment refuelling water storage tank. In Russia has been developed the so-called NPP-2006 project of a VVER-1200 nuclear power plant with a V-392M reactor unit. To provide the safety, protection passive systems which don’t depend upon human errors are widely used in this project. Among these are hydrotanks of the second stage and passive heat removal system. In the presented paper an overview of passive core cooling systems for next generation NPPs is given.

    DigitalMaschinenbau und Mechatronik

    Vortrag

    Daniel Heinz

    Virtuelles Testen mittels Simulation

    Posterpräsentation

    5. Tag der Forschung, Deggendorf

    2018

    NachhaltigMaschinenbau und Mechatronik

    Vortrag

    Robert Mnich

    Modellierung des Vergasungsprozesses von Holz

    Posterpräsentation

    5. Tag der Forschung, Deggendorf

    2018

    MobilMaschinenbau und MechatronikTC Cham

    Vortrag

    Frank Denk, Continental Automotive GmbH

    Inductive Charging - Norms, Standards and Interoperability

    2. Fachsymposium Elektromobilität der Zukunft, Deggendorf

    2017

    MobilMaschinenbau und MechatronikTC Cham

    Vortrag

    Frank Denk, Continental Automotive GmbH

    Systembeschreibung für direkteinspritzende Ottomotoren und elektromagnetische Ansteuerstrategien

    Symposium Elektromagnetismus 2017, Stuttgart/Ostfildern

    2017

    DigitalFraunhofer AWZ CTMTMaschinenbau und Mechatronik

    Zeitschriftenartikel

    Thomas Fischer, Mario Salzinger, Daniel Heinz, Jochen Hiller

    Quantitative Untersuchung zur Reduzierung der Messzeit in der dimensionellen Computertomographie

    Bavarian Journal of Applied Sciences, vol. 3, no. 1, pp. 282-296

    2017

    DOI: 10.25929/jy3v-pm72

    Abstract anzeigen

    Einer der häufig genannten Nachteile für Computertomographie-(CT-)Anwender in der industriellen Praxis ist der Zeitfaktor. Für einen messtechnisch auswertbaren CT-Scan ist das System in den meisten Fällen mindestens 30 Minuten lang ausgelastet, je nach Prüfobjekt und Genauigkeitsanforderungen oft auch deutlich länger. Ziel dieser Untersuchung ist es, mit derzeitig möglichen Methoden herauszufinden, wie die Scanzeiten verringert werden können und wie sich diese Reduzierung auf die Qualität der Messung bezüglich Messgenauigkeit und Wiederholgenauigkeit auswirkt. Nach Auswahl und taktiler Referenzmessung eines Prüfkörpers werden mit dem 360° Stop&Go-Verfahren sowie mit zwei weiteren Scanstrategien, der 180° CT und der FlyBy-CT, Messdaten erzeugt. Es folgt ein Vergleich der Messergebnisse und der Messzeiten. Bei der 180°-Messung wird das Objekt intermittierend um die Hälfte rotiert, wohingegen beim FlyBy-Modus eine kontinuierliche Objektbewegung ohne Abbremsung erfolgt. Beide Messverfahren haben sich für diverse Anwendungsszenarien bewährt. Die größte Messzeitreduzierung ist beim Einsatz des FlyBy-Modus zu erwarten. Im Vergleich dazu bietet der 180°-Modus ebenfalls Vorteile, auch wenn die erwartete Scanzeit gegenüber dem FlyBy-Modus länger ist. Mit diesem lässt sich trotz der Möglichkeit zur Bildmittelung Scanzeit einsparen, gegenüber dem herkömmlichen 360°-Scanverfahren lässt sich aber zudem bei gleichbleibender Zeit eine erhöhte Rauschreduzierung erzielen. One of the biggest disadvantages operators complain about in the field of industrial computed tomography is the time factor. CT scans for measuring purposes will usually take at least 30 minutes, yet often noticeably longer, depending on the specimen and accuracy requirements. The purpose of this research is to determine how scan times can be reduced by applying the currently available methods and to assess in which way this reduction influences measurement quality with regards to measurement accuracy and repeatability. After choosing a test specimen and performing tactile measurements to determine the nominal values, measurement data is generated by using the 360° Stop&Go procedure, the 180° CT and the FlyBy-CT. Then the measurement results and durations are compared with each other. Measurements using the 180° procedure are performed by intermittently rotating the object by 180 degrees, whereas the FlyBy mode involves a continuous object movement without deceleration. Both CT modes are well proven in various applications. Out of all three methods, the FlyBy mode has the greatest potential for reducing overall scan times. In comparison, the 180° mode also has its advantages, although the expected scan times are longer compared to the FlyBy mode. This CT mode offers the opportunity to reduce scan times despite the option of image averaging. In addition, compared to the conventional 360° scan procedures, it is possible to achieve a higher level of noise reduction within a constant time.

    NachhaltigMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    S. Buchholz, W. Klein-Hessling, Giuseppe Bonfigli, Nadine Kaczmarkiewicz, N. Neukam, F. Schäfer, T. Wagner

    The Code System AC2 for the Simulation of Advanced Reactors within the Frame of the German EASY Project

    Proceedings of the 17th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-17) [September 3-8, 2017; Qujiang Int’l Conference Center, Xi’an, Shaanxi, China]

    2017

    NachhaltigMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    S. Buchholz, A. Schaffrath, Giuseppe Bonfigli, Nadine Kaczmarkiewicz, N. Neukam, F. Schäfer, T. Wagner

    Evidence of Design Basis Accidents Mitigation Solely with Passive Safety Systems within the Frame of the German EASY Project

    Proceedings of the 17th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-17) [September 3-8, 2017; Qujiang Int’l Conference Center, Xi’an, Shaanxi, China]

    2017

    NachhaltigMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    Nadine Kaczmarkiewicz, Giuseppe Bonfigli, S. Leyer, T. Wagner

    Influence of Two-Phase Reverse Flow in the Passive Core Flooding System: Experiments and Simulations within the Frame of the German EASY Project

    Proceedings of the 17th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-17) [September 3-8, 2017; Qujiang Int’l Conference Center, Xi’an, Shaanxi, China]

    2017

    NachhaltigElektrotechnik und MedientechnikIQMAMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    Günther Benstetter, Alexander Hofer, D. Liu, Werner Frammelsberger, M. Lanza

    Chapter 3: Fundamentals of CAFM Operation Modes

    Conductive Atomic Force Microscopy: Applications in Nanomaterials, Weinheim

    2017

    ISBN: 978-3-527-34091-0

    NachhaltigElektrotechnik und MedientechnikIQMAMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    Tobias Berthold, Günther Benstetter, Werner Frammelsberger, Manuel Bogner, R. Rodríguez, M. Nafría

    Protective nanometer films for reliable Cu-Cu connections

    Best Paper Award

    Proceedings of the 28th European Symposium on Reliability of Electron Devices, Failure Physics and Analysis (ESREF) [25-28 September, 2017; Bordeaux, Frankreich]

    2017

    NachhaltigElektrotechnik und MedientechnikIQMAMaschinenbau und Mechatronik

    Zeitschriftenartikel

    Tobias Berthold, Günther Benstetter, Werner Frammelsberger, R. Rodríguez, M. Nafría

    Numerical Study of Hydrodynamic Forces for AFM Operations in Liquid Scanning (Article ID 6286595, 12 pages)

    Scanning, no. Article ID 6286595, pp. 1-12

    2017

    DOI: 10.1155/2017/6286595

    Abstract anzeigen

    For advanced atomic force microscopy (AFM) investigation of chemical surface modifications or very soft organic sample surfaces, the AFM probe tip needs to be operated in a liquid environment because any attractive or repulsive forces influenced by the measurement environment could obscure molecular forces. Due to fluid properties, the mechanical behavior of the AFM cantilever is influenced by the hydrodynamic drag force due to viscous friction with the liquid. This study provides a numerical model based on computational fluid dynamics (CFD) and investigates the hydrodynamic drag forces for different cantilever geometries and varying fluid conditions for Peakforce Tapping (PFT) in liquids. The developed model was verified by comparing the predicted values with published results of other researchers and the findings confirmed that drag force dependence on tip speed is essentially linear in nature. We observed that triangular cantilever geometry provides significant lower drag forces than rectangular geometry and that short cantilever offers reduced flow resistance. The influence of different liquids such as ultrapure water or an ethanol-water mixture as well as a temperature induced variation of the drag force could be demonstrated. The acting forces are lowest in ultrapure water, whereas with increasing ethanol concentrations the drag forces increase.

    NachhaltigElektrotechnik und MedientechnikIQMAMaschinenbau und Mechatronik

    Zeitschriftenartikel

    Tobias Berthold, Günther Benstetter, Werner Frammelsberger, Manuel Bogner, R. Rodríguez, M. Nafría

    Protective nanometer films for reliable Cu-Cu connections

    Microelectronics Reliability, vol. 76-77, no. September, pp. 383-389

    2017

    DOI: 10.1016/j.microrel.2017.07.001

    DigitalFraunhofer AWZ CTMTMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    Peter Hornberger, Christian Aichinger, Jochen Hiller

    Dimensionelles Messen mit Computertomographie

    Handbuch zur industriellen Bildverarbeitung. Qualitätssicherung in der Praxis

    2017

    ISBN: 978-3-8396-1226-2

    DigitalFraunhofer AWZ CTMTMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    Jochen Hiller, Peter Hornberger, Thomas Miller

    Dimensional Metrology for Industrial Computed Tomography

    Handbook of X-ray Imaging - Physics and Technology, Boca Raton, FL, USA

    2017

    ISBN: 9781498741521

    DigitalFraunhofer AWZ CTMTMaschinenbau und Mechatronik

    Zeitschriftenartikel

    Simon Rettenberger, F. Bittner, H.-J. Endres, Jochen Hiller

    Blick in belastete Composite-Bauteile

    Konstruktion (Zeitschrift für Produktentwicklung und Ingenieur-Werkstoffe), no. 5

    2017

    DigitalFraunhofer AWZ CTMTMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    Gabriel Herl, Simon Rettenberger, Jochen Hiller

    Fusion mehrerer Computertomographie-Aufnahmen zur Verbesserung der Bildqualität

    Forschungsbericht 2016/2017 der Technischen Hochschule Deggendorf

    2017

    DigitalFraunhofer AWZ CTMTMaschinenbau und Mechatronik

    Zeitschriftenartikel

    Jochen Hiller, N. Sawczyn, D. Imkamp, E. Uhlmann

    Untersuchungen zur Messunsicherheit und Wirtschaftlichkeit dimensioneller Computertomographie-Messungen an ausgewählten Beispielen

    tm - Technisches Messen, vol. 84, no. 5, pp. 336-347

    2017

    Abstract anzeigen

    Die industrielle Computertomographie (CT) wird zunehmend für die zerstörungsfreie Prüfung von Bauteilen als Instrument der fertigungsbegleitenden Qualitätssicherung eingesetzt. Ein Vorteil gegenüber taktilen oder optischen Messverfahren ist insbesondere die Möglichkeit, sowohl außen- als auch innenliegende Geometriemerkmale zerstörungsfrei zu erfassen. In diesem Beitrag werden anhand ausgewählter Bauteile Möglichkeiten zur Steigerung der Wirtschaftlichkeit von CT-Messungen durch gleichzeitige tomographische Erfassung mehrerer Bauteile im Messvolumen untersucht und die Messunsicherheit für die einzelnen Aufnahmeszenarien experimentell ermittelt.

    NachhaltigMaschinenbau und Mechatronik

    Beitrag (Sammelband oder Tagungsband)

    Josef Stettmer

    Process optimization at small and medium-sized enterprises: production of small and medium-sized batches

    Proceedings of SPIE 10326 (Fourth European Seminar on Precision Optics Manufacturing, 1032601 [April 4th-5th 2017, Teisnach])

    2017

    DOI: 10.1117/12.2275028

    NachhaltigMaschinenbau und Mechatronik

    Zeitschriftenartikel

    Thomas Stirner, David Scholz, J. Sun

    Hartree-Fock simulation of the (0 0 0 1) surface of hematite with a posteriori calculation of the correlation energy

    Computational Materials Science, vol. 137, no. September, pp. 340-345

    2017

    DOI: 10.1016/j.commatsci.2017.06.011

    Abstract anzeigen

    The results of Hartree-Fock simulations of the (0 0 0 1) surface of hematite including an a posteriori calculation of the correlation energy are presented. Structural as well as electronic and magnetic properties of the surface atoms are considered. Infrared and Raman bands of the hematite slab are also presented. The calculated surface relaxation is shown to be in good agreement with experimental data originating from a recent LEED analysis. The iron-oxygen bond at the single-iron-terminated surface is shown to be less ionic than in the bulk. Also, the magnetic dipole moment of the surface iron atom is smaller than in the bulk. Finally, the surface energy of the (0 0 0 1) facet is presented for hematite, and for comparison also for α-alumina and α-chromia for various hybrid functionals. Here it is shown that the effects of electron correlation play an important role for hematite and chromia due to their localized 3d electrons.